Analysis of Methods for Treating Ceramic Kiln Exhaust Gases
In China, both flue-gas dust removal and desulfurization have reached a relatively mature stage, whereas research on denitrification remains at the experimental and developmental phase. From a trend‑based perspective, if adequate attention is not paid to NOx, it could very well supplant SO2 as the primary pollutant in the atmosphere.
In China, flue‑gas dust removal and desulfurization have both reached relatively mature stages, whereas denitrification technology remains at the research and experimental phase. From a developmental perspective, if NOx is not given sufficient attention, it could very well supplant SO2 as the primary pollutant in the atmosphere. As environmental concerns continue to grow and in line with the Scientific Outlook on Development and the goal of building a harmonious socialist society, future flue‑gas treatment will need to integrate desulfurization, denitrification, and dust removal into a single, comprehensive system. In recent years, while industrial development has continued to expand, the quality of living environments has steadily deteriorated, making “energy conservation and emissions reduction” a central issue in the industrial sector. The ceramics industry, long regarded as a “high‑consumption, high‑pollution, high‑emission” sector, has been subject to repeated government policies mandating rectification and transformation. Consequently, energy conservation and emissions reduction have become critical components of the ceramics industry. This paper primarily examines the flue‑gas characteristics of ceramic kilns and proposes an integrated approach that combines modified SNCR low‑temperature denitrification with a semi‑dry desulfurization and dust‑removal process to treat kiln exhaust. It also provides a brief analysis of the technology’s performance and structural features.
1. Preface
With the continuous development of the national economy, China’s ceramic industry has also experienced rapid growth. According to statistics, the production of ceramic wall and floor tiles surged from 272 million m² in 1991 to approximately 9 billion m² in 2012, placing China at the top of the world rankings and accounting for roughly two-thirds of global output—a highly promising trend. However, the associated adverse environmental impacts—particularly flue‑gas pollution from kilns—are becoming increasingly pronounced. In China, 90% of atmospheric SOx, 85% of CO2, 80% of particulate matter (PM), and 50% of NOx emissions originate from ceramic kilns, steam boilers, and various other industrial kilns. Data indicate that, in the sectors of daily-use ceramics and architectural ceramics alone, there are currently more than 3,000 kilns, representing about 70% of the country’s total kiln fleet. Consequently, addressing flue‑gas pollution from ceramic kilns has emerged as a critical research priority.
Currently, most industries employ wet‑type desulfurization and dust‑removal tower systems. While this approach ensures that SO₂ emissions meet regulatory limits, it is difficult to achieve compliance with the new emission standards for the ceramic industry (GB 25464‑2010). Moreover, wet flue‑gas desulfurization generates substantial desulfurization wastewater, further increasing the land footprint required for wastewater treatment. The resulting rise in wastewater volume, coupled with the additional space demands of such systems, also leads to higher energy consumption during production [3]. In recent years, a novel desulfurization and dust‑removal technology tailored for ceramic kiln exhaust—spray‑drying semi‑dry flue‑gas cleaning—has emerged in the market. This technology has already demonstrated commercial success in domestic desulfurization applications, delivering dust‑removal and desulfurization performance comparable to wet‑process methods.
In China, flue‑gas pollution control has primarily focused on dust removal and SO₂ abatement. As environmental pollution intensifies and air‑quality standards become more stringent, the treatment of NOx has also been placed high on the agenda. At present, China has imposed strict emission limits on NOx from industrial kilns, in accordance with the Comprehensive Emission Standard for Air Pollutants (GB 25464‑2010). However, the SCR denitrification process requires flue‑gas temperatures in the range of 300–420°C, entails high capital and operating costs, and occupies a large footprint, making it unsuitable for ceramic‑industry kilns where land is scarce.
This paper, taking into account the characteristics of flue gases from ceramic industrial kilns, analyzes and discusses the issue from a practical application perspective, proposing an integrated approach that combines modified SNCR low-temperature denitrification with a semi-dry desulfurization and dust removal process to treat the exhaust gases from ceramic kilns.
2. Overview of the Integrated Technology for Modified SNCR Low-Temperature Denitrification and Semi-Dry Desulfurization and Dust Removal
The integrated technology of modified SNCR low-temperature denitrification combined with semi-dry desulfurization and dust removal builds upon existing equipment by adding appropriate auxiliary units to achieve simultaneous desulfurization, denitrification, and dust removal. The system ingeniously incorporates a denitrification unit and extends certain pipeline sections, operating at temperatures between 300 and 450°C to ensure safe, stable, and continuous operation.
3. Modified SNCR Low-Temperature Denitrification Technology System
3.1 Process Flow of the Modified SNCR Low-Temperature System
The modified SNCR low-temperature system is, in essence, an enhanced version of the conventional SNCR technology. Its fundamental principle remains the same as SNCR: within a specific temperature range (300–450°C), dry reductants are used to reduce NOx. The primary reaction is as follows:
NOx + dry reductant + O2 → N2 + H2O
Unlike SNCR, the modified SNCR low‑temperature system injects finely atomized droplets of a modified reagent solution into designated sections of the flue gas duct and ensures their uniform distribution. The modified SNCR low‑temperature system is a denitrification reaction occurring within the flue gas pipeline, and the degree of fine dispersion of the reagent‑solution droplets across the target temperature window in the duct is a critical factor influencing system performance. The system stores a reagent solution at an appropriate concentration and circulates it to the duct side; compressed air supplied by the plant further dilutes the solution to a preset concentration, after which a metering module precisely doses the required amount of reagent solution for the denitrification reaction and delivers it to the spray nozzles. The nozzles employ mechanical atomization and carrier air to inject the desired reagent solution into specific regions of the duct. During system optimization and commissioning, the atomization characteristics and flow rate of each nozzle are further adjusted based on the actual operating load and NOx concentration within the duct, ensuring optimal alignment with system requirements. The denitrification unit can be networked with online monitoring systems; leveraging feedback data—such as post‑treatment concentrations and NH3 slip levels—it automatically and accurately regulates parameters like injection dosage and reagent concentration, thereby achieving compliant emissions while minimizing operating costs.
The modified SNCR system primarily consists of a reagent storage tank, a reagent delivery and regulation system, a reagent feedback sensor assembly, a touch‑screen control panel, and an automatically adjustable reagent spray nozzle assembly.
3.2 Technical and Process Characteristics
Compared with similar technologies and processes, this system has the following features:
(1) A modified reagent is used as the reducing agent; it is non-toxic, harmless, urea-free, and does not cause ammonia slip.
(2) No need to store or handle pressurized, hazardous anhydrous ammonia or ammonium hydroxide, nor the associated safety equipment;
(3) Using liquid rather than gaseous reagents enables more precise control of the injection pattern and distribution, ensures thorough mixing with flue gas, and, at an appropriate temperature, maximizes reagent utilization, thereby effectively improving the efficiency of the reducing agent.
(4) The reducing agent exhibits strong penetration capability, with an appropriate droplet size and uniform distribution, ensuring effective mixing with NOx in the flue gas.
(5) Each project’s modified‑agent spraying system is custom‑designed, featuring wall‑mounted sprayers, wall‑mounted sprayers with telescopic extension, and multi‑nozzle gun‑type sprayers. In areas where the reach of a short‑length modification‑agent spray gun is insufficient, the multi‑nozzle gun ensures thorough coverage of the sprayed modification‑agent solution.
4 Semi-Dry Desulfurization and Dust Removal Process
Ceramic industrial kiln flue gases typically exhibit the following characteristics: due to the high temperature of the exhaust from the firing kiln, waste heat is recovered by routing this exhaust into an upstream process—the drying kiln—resulting in a relatively low flue gas outlet temperature. Furthermore, during the spray‑drying of ceramic powders, dust particles absorb heat from liquid droplets, thereby capturing SO₂ from the flue gas; some of this SO₂ is subsequently released during the kiln’s drying and firing stages, while additional SO₂ is generated by fuel combustion. Consequently, the SO₂ concentration in the kiln exhaust is relatively high. At the same time, moisture produced during the drying process in the drying kiln is carried away with the exhaust, leading to flue gases from ceramic kilns that are characterized by low temperature, high humidity, and elevated pollutant concentrations [2].
The flue gas treatment system described in this paper, employing a “semi‑dry desulfurization and dust removal technology,” comprises two main process stages—“dry desulfurization” and “baghouse dust collection”—along with associated fan‑duct systems and electrical control systems. Its fundamental operating principle is as follows: a measured quantity of alkaline solution is sprayed into a cooling‑and‑desulfurization tower; the high‑temperature evaporation of the desulfurization droplets cools the flue gas while simultaneously removing sulfur oxides. The cooled flue gas then enters a dust collector, where particulate matter and desulfurization byproducts are captured and purified. Finally, the treated gas is discharged through a fan and stack in compliance with emission standards. The detailed process flow is illustrated in Figure 3.
4.1 Cooling and Desulfurization System
4.1.1 System Composition and Process
The cooling and desulfurization system employs “spray-drying cooling and desulfurization technology.” The system primarily comprises a cooling and desulfurization tower, a cooling and desulfurization water system, and a compressed air system, with its process flow illustrated in Figure 4.
4.1.2 System Configuration and Architecture
(1) Cooling and Desulfurization Tower
This system employs a cooling and desulfurization tower as the cooling and desulfurization unit, which consists of a cylindrical shell, a dust hopper, spray nozzles, flow‑diverting baffles, water pipes, air pipes, and other components.
After the flue gas enters the cooling and desulfurization tower, it flows uniformly upward under the guidance of flow‑diverting baffles. The nozzles are dual‑stream air–water type, atomizing the scrubbing solution into droplets approximately 50 μm in diameter. Upon contact with the high‑temperature flue gas, these droplets carry away heat, thereby reducing the gas temperature, while the alkali in the solution reacts with SO₂ in the flue gas, absorbing and neutralizing it to bring its concentration within the relevant national emission standards. Once the droplets have fully evaporated, the flue gas proceeds to the dust collector.
The particulate matter in the flue gas settles into the ash hopper under gravity, and after being captured by the baghouse, it is discharged through the ash discharge valve under the action of a vibrator.
(2) Preparation of the Cooling and Desulfurization Solution
In accordance with the system’s cooling and desulfurization requirements, the concentration of the cooling‑desulfurization solution is precisely adjusted using a pump and a flow‑control valve. Under pressure from a stainless‑steel multistage centrifugal pump, the solution is atomized into extremely fine droplets by an air–water dual‑flow nozzle and injected into the cooling‑desulfurization tower.
4.3 System Features
(1) Unique structural design, high cooling and desulfurization efficiency, meeting system requirements.
Drawing on experience in flue-gas treatment, the designed cooling tower integrates the advantages of multiple cooling and desulfurization systems. Equipped with sensors and an automated control system, it ensures precise operation of the relevant cooling and desulfurization processes, enabling the flue gas to maintain stable temperature and humidity levels.
(2) Small footprint
The cooling and desulfurization tower features a vertical design, occupying a very small footprint; moreover, the solution tank and pumps also require minimal space.
(3) Simple process, cost-effective investment
Based on the actual temperature of the high‑temperature flue gas, the system automatically adjusts the flow rate, enabling convenient temperature control that not only meets system requirements but also reduces operating costs. Moreover, the operation of the cooling tower has no impact on the furnace pressure of the ceramic melting furnace.
(4) The system is stable and reliable, with simple maintenance.
The entire system has few moving parts, and the cooling and desulfurization solution is made with clean tap water, eliminating any risk of blockage.
The flue gas, after passing through the desulfurization tower, enters the baghouse dust collector, effectively and reliably addressing issues such as excessive particulate matter and elevated levels of desulfurization reaction products that can lead to dust emissions exceeding regulatory limits.
All equipment maintenance on the cooling and desulfurization tower can be performed without entering the tower itself; the maintenance work does not in any way affect the operation of the ceramic furnace, nor does its online or offline status impact the furnace’s pressure.
Therefore, system maintenance is straightforward, the system failure rate is low, and equipment has a long service life, resulting in substantial savings in both manpower and financial resources.
(5) The tower products are easy to handle, and no wastewater is generated.
The solution sprayed into the cooling desulfurization tower evaporates directly within the tower; some of the particulate matter settles into the tower’s ash hopper, while the remainder proceeds to the next process stage, where it is captured by a dust collector. All by‑products are dry solids with stable properties, non‑toxic and harmless. The collected dust can be disposed of directly. The process is easy to manage and generates no secondary pollutants such as wastewater or exhaust gases.
Compared with other cooling‑and‑desulfurization methods, this semi‑dry cooling‑and‑desulfurization process significantly reduces labor, capital investment, maintenance, and the costs associated with handling the cooled byproducts. Consequently, the overall advantages of this technology are quite pronounced.
In summary, the advantages of the semi-dry process include: no water‑treatment system, no white‑smoke formation, low operating costs, easy maintenance, no impact on product quality or output, and the ability to meet emission standards under all weather conditions.
4.4 Dust Collection System
In view of the characteristics of kiln flue gases, a baghouse is selected as the dust collector for the semi‑dry dust removal system. Currently, the most widely used baghouses include pulse‑jet baghouses and chamber‑type baghouses; Table 1 presents an analytical comparison of these two types.
As the above comparison demonstrates, pulse‑jet baghouse dust collectors are more suitable for flue gas filtration in kilns.
4.4.1 Dust Removal — Online Pulse-Jet Baghouse Dust Collector
The gas purification method employed by the online pulse‑jet baghouse is external filtration. The dust collector comprises an upper casing, a middle casing, a hopper, a bag assembly, a blow‑off system, an ash discharge valve, pulse valves, and monitoring and control systems. The filter bags are secured to the perforated plate via bag cages. Each row of filter bags is fitted with a blow pipe at its upper end; this pipe is equipped with small nozzles aligned with the center of each bag. A pulse valve connected to an air compressor is mounted upstream of the blow pipe, and the electromagnetic pulse valve is linked to a pneumatic cylinder. The controller periodically generates brief pulse signals, which, through a sequence‑control valve, precisely regulate the opening of each pulse valve.
During operation, dust-laden exhaust gas enters the hopper of each unit through the inlet at the lower part of the middle housing. Coarse particulate matter, subjected to inertial impaction and natural settling, falls directly into the hopper, while the remaining fine particles are carried by the airflow into the filtration zone of the middle housing. Dust accumulates on the outer surface of the filter bags, and the filtered clean gas passes through the bags, exits via the upper housing, and is discharged through the exhaust duct, thereby achieving the purpose of dust removal.
As the filtration process continues, the layer of dust accumulating on the outer surface of the filter bags steadily grows, causing the pressure drop across the dust collector to rise gradually. When the accumulated dust reaches a certain threshold, the cleaning control system issues a cleaning signal, and the control valves sequentially open the pulse valves. Upon opening, the jet pipe connected to the pulse valve communicates with the air cylinder, and high‑pressure air is ejected at extremely high velocity through the nozzle. This high‑velocity airflow enters the filter bag, causing it to expand violently and generating impact vibrations. Simultaneously, an instantaneous reverse airflow directed from the inside to the outside sweeps away the dust adhering to the outer surface and entrained into the interior of the bag. The dislodged dust falls into the dust hopper and is eventually discharged via the ash discharge device. The filter bags are cleaned in alternating cycles, and after one complete cycle, the sequence resumes.
4.4.2 Design Features of Pulse-Jet Baghouse Dust Collection Equipment
Its technical features:
(1) The filter media has been technologically improved, resulting in higher air permeability, lower resistance, and greater energy efficiency.
(2) The corrosion‑resistant materials have been upgraded, eliminating the delamination that can occur after prolonged use and extending the service life.
(3) The pulse‑jet solenoid valves used for dust collector cleaning have been upgraded from conventional right‑angle types to high‑performance submerged pulse valves. Although submerged valves are more expensive than right‑angle models, they deliver a larger instantaneous air flow, ensuring more thorough cleaning and longer service intervals, while exhibiting lower pressure drop. This enhances the system’s load‑carrying capacity, broadens the allowable range of supply‑air pressures, and enables operation even under relatively low supply pressures—down to as low as 3.5 kg/cm².
(4) In this dust collector, the control system has been optimized by replacing mechanical control components with PLC-based control and incorporating a touch-screen interface that displays real-time operating status and process parameters of all equipment. Additionally, the switches used to monitor valve positions have been upgraded from conventional mechanical limit switches to inductive electronic switches, effectively reducing the risk of accidents caused by failure of the limit switches.
5 Conclusion
In China, flue‑gas dust removal and desulfurization have both reached a relatively mature stage, whereas denitrification technology remains in the research and experimental phase. From a developmental perspective, if NOx is not given sufficient attention, it could very well supplant SO2 as the primary pollutant in the atmosphere. As environmental concerns continue to grow and in line with the Scientific Outlook on Development and the goal of building a harmonious socialist society, future flue‑gas treatment will need to integrate desulfurization, denitrification, and dust removal into a single, comprehensive system. The combination of modified SNCR low‑temperature denitrification with semi‑dry desulfurization and dust‑removal technologies aligns well with this trend. Moreover, this integrated system can significantly enhance the efficiency of treating kiln exhaust gases, address the high energy consumption and elevated costs associated with kiln operations, and help drive the transformation and upgrading of the ceramics industry.
Keywords:
Analysis of Methods for Treating Ceramic Kiln Exhaust GasesPrevious item: Development Trends of Refractory Materials for Glass Melting Furnaces